Sunday, 05 Sep 2010
Home Automatic dosing units for brighteners
Italian - ItalyDeutschEspañolFrenchPortuguêsEnglish
 
Automatic dosing units for brighteners PDF Print E-mail

dosatori automatici

 

The automatic dosing units automatically replenish the liquid products in the plating baths, ensuring the concentration remains stable in the bath. Each model features a control panel with
two 6-digit displays.

The first indicates the total ampere-hours, minutes or seconds (time units are user selectable). The other indicates the ampere-time countdown (which can be programmed with a simple operation) before the pump is started to replenish the product.

The dosing unit and pump working time are set via a practical, easy-to-use menu, which is nonetheless protected against inadvertent editing. It checks the current absorbed during the whole plating phase with the utmost precision, producing an unbeatably reliable constant replenishment action.

All models can be connected to any rectifier. They can be built with one or more pumps as needs dictate (e.g.: simultaneous dosing with different quantities of three products that cannot be mixed in a single container). Furthermore, the current delivered by two or more rectifiers can be added together, thus achieving a considerable reduction in costs.

 

TECHNICAL SPECIFICATIONS

• Power supply: single-phase 230V ac +/- 10% 50/60Hz (other voltages on request).
• Counter range: 0 - 60 mV.
• Pump pressure: 10 Atm.
• Max. distance: 10 metres.
• Head: 1,5 metres.
• Max. product viscosity 200 cps.
• Flow rate: 10 litres/h for BL and 50 cc for GLS.
• Settings: Ampere-seconds / Ampere-minutes / Ampere-hours.
• Display: six-digit; Total / Preset.
• Dimensions: A = 350 mm. B = 300 mm. C = 200 mm.
• Weight: 15 kg.

 

We can build any kind of dosing unit to the customer's specifications.